1B20, 1B27, 1B30, 1B40, 1B50 Operation and use
HATZ
35Operator's Manual
Max. permissible forces on the speed control lever and stop pin
F
<
15 N
STOP
76.5°
STOP
F 30 N
M Nm
<
<
START
2.3
7.2 Performing tests
Before starting
Before starting the engine, several tests need to be performed to ensure the
machine is working properly.
Procedure
Step Test
1 The machine is standing securely and on a level surface.
2 The installation location is adequately ventilated.
3 There is a sufficient amount of fuel in the fuel tank (see chapter
7.7 Refueling, page 50).
4 There is a sufficient amount of engine oil in the engine housing
(see chapter 7.6 Checking the oil level and adding oil if neces-
sary, page 47).
5 The starter rope of the recoil start does not exhibit abrasion
(hand start).
6 Fill the oil bath air filter (option) with engine oil (see chapter 7.6.2
Oil level in the oil bath filter (option), page 49).
7 No persons are located in the danger zone of the engine or ma-
chine.
8 All safety equipment is in place.