Faults 3-4L43C, 3-4M43, 3-4M43Z
90
HATZ
Manual
The engine starts, but does not continue running after the starter is
switched off.
Possible causes Remedy Chapter
Machine is not uncou-
pled.
If possible, separate the engine
from the machine by uncou-
pling it.
Fuel prefilter is
clogged.
Change the fuel prefilter. 8.2.9 Changing
the fuel prefilter,
page 63
Main fuel filter is
clogged.
Change the main fuel filter 8.2.14 Change
the main fuel fil-
ter, page 73
Fuel supply is inter-
rupted.
Systematically check the entire
fuel supply.
Stop signal from monitoring elements that are associated with the au-
tomatic switch-off (optional):
No oil pressure. Check the oil level. 7.8 Checking the
oil level and
adding oil if nec-
essary, page 43
Faulty three phase
alternator.
Contact Hatz service.
Engine switches off spontaneously during operation.
Possible causes Remedy Chapter
The tank ran out of fuel
during operation.
Fill with fuel. 7.6 Refueling,
page 41
Fuel prefilter or main
fuel filter is clogged.
Change the fuel filter. 8.2.9 Changing
the fuel prefilter,
page 63
8.2.14 Change
the main fuel fil-
ter, page 73
Poly v belt torn. Renew the poly v belt. 8.2.15 Renewing
the poly v belt
and checking the
function of the
switch-off unit,
page 76
Mechanical faults. Contact Hatz service.