6.2 Configuration
The configuration defines which data content is exchanged in cyclical data
traffic. The following data is available for selection:
Input values:
Name Meaning Length
Gross Gross measured value 1 or 2
words
Net Net measured value (gross minus tare value) 1 or 2
words
Max Content of maximum store 1 or 2
words
Min Content of minimum store 1 or 2
words
Pk-Pk Peak-to-peak, difference between max and min 1 or 2
words
Status1 Status word with status of the limit switches and gen. error
bits
1 word
Status2 Double status word with differentiated error flagging 2 words
Output values:
Name Meaning Length
Control word Control word to trigger taring, zeroing, clearing the peak
value store, parameter set selection, Autocal etc.
1 word
Limit1 Level at which limit switch 1 responds 1 or 2
words
Limit2 Level at which limit switch 2 responds 1 or 2
words
Limit3 Level at which limit switch 3 responds 1 or 2
words
Limit4 Level at which limit switch 4 responds 1 or 2
words
The formats of the cyclically communicated data content are specified in detail
in chapter 6.3. The measured values are offered optionally as 16-bit integer,
32-bit integer or 32 bit float. The values are always scaled to physical size
with the number of decimal places of your choice. Information on whether the
16-bit or 32-bit format is used and on the number of decimal places is defined
in the parameter assignment message.
Typical combinations are predefined in the GSE file. If you require other
combinations you can expand the GSE file accordingly using the following
specifications.