63
T12
A197910.0 en HBM
15.2 Nominal (rated) torque 2 kNVm to 10 kNVm
Type T12
Accuracy class 0.03
Torque measuring system
Nominal (rated) torque M
nom
kNm 2 3 5 10
Nominal (rated) rotational speed n
nom
Option 3, code L
1)
rpm
12 000 10 000
Option 3, code H
1)
rpm 16 000 14 000 12 000
Non-linearity including hysteresis, related to
nominal (rated) sensitivity
Fieldbuses, frequency output 10 kHz/60 kHz
For a max. torque in the range:
between 0% of M
nom
and 20% of M
nom
> 20% of M
nom
and 60% of M
nom
> 60% of M
nom
and 100% of M
nom
%
%
%
<"0.006 (optional <"0.004)
<"0.013 (optional <"0.007)
<"0.02 (optional <"0.01)
Voltage output
For a max. torque in the range:
between 0% of M
nom
and 20% of M
nom
> 20% of M
nom
and 60% of M
nom
> 60% of M
nom
and 100% of M
nom
%
%
%
<"0.015
<"0.035
<"0.05
Relative standard deviation of repeatability per
DIN 1319, related to the variation of the output
signal
Fieldbuses/frequency output %
"0.01
Voltage output %
"0.03
Temperature effect per 10 K in the nominal
(rated) temperature range
on the output signal, related to the actual
value of the signal span
Fieldbuses/frequency output
%
"0.03
Voltage output %
"0.1
on the zero signal, related to the nominal
(rated) sensitivity
Fieldbuses/frequency output
%
"0.02 (optional "0.01)
Voltage output %
"0.1
Nominal (rated) sensitivity (span between
torque = zero and nominal (rated) torque)
Frequency output 10 kHz/60 kHz kHz 5/30
Voltage output V 10
Sensitivity tolerance (deviation of the actual
output quantity at M
nom
from the nominal (rated)
sensitivity)
Frequency output
%
"0.05
Voltage output %
"0.1
1)
See page 87.