Tin the shield braid on end B.
Use
a minimum amount
of heat and avoid melting the inner insulation.
(
d
Connect the coaxial cable center conductor
at
end
B
to l"g
7
of relay
F
6-1
1.
(4
Connect the center conductor of the rekinis coaxial
cable coming from grommet T to lug 4 of relay
F
6-1
1.
Be
sure this lead does not touch any other lug of
the relay.
Detail
4-12H
(
6
Refer to Detail 4-12H and position the exposed shields
of the coaxial cables connected in the two preceding
steps,
over
the long solder lug at R. Bend the solder
lug back over both shield braids and solder.
Use
a
minimum, but adequate, amount of heat.
(4
Connect the center conductor at the free end of the
coaxial cable to the center conductor of the coaxial
fitting at
L
(S-1
1.
Connect the shield wires to lug
2
of
phono socket
U
6-11.
($;
Cut one lead of a 100 kSZ resistoi
(brown-black-yellow) to 314" and the other lead to
1".
Place a 112" length of black sleeving on the 314"
lead and a 314" length of black sleewing on the 1"
lead.
J
.
(
1
Connect the 314" lead of the 100 kSZ resistor to lug
8
6-21 and the 1" lead to lug 2 6-31 of relay
F
as
shownin inset drawing
2
of the Pictorial.
Refer to
Pictorial
4-13
(Wd-out from
Page
501 for the
following
steps.
Refer
to Detail 4-13A for the following three steps.
(dl Remove a knurled nut from each of the
two
circuit
breakers (#65281.
/A
HEX~GONAL
NUT
*F,
BREAKER
Detail
4-13A
(4
Position the face of each hexagonal nut 114'* from the
end of the mounting bushing.
(1/(
Mount a circuit breaker on the chassis rear apron at
AB.
Use
the knurled nut provided. NOTE: For
convenience in wiring, position the solder lugs to
provide the maximum distance between the chassis
and the lugs.
(
4
Similarly, mount the other circuit breaker at
AA.
/
f'
NOTE: In ,the following Aeps
connectdith
the process.
--
-
..
/
Page 52
-
~ight
column.
,.
UI
Replace the "Note" and the next three.steps.
1
NOTE: In the following steps the fan motor will
4
I
connected. Be careful not to tear the motor leads out
d
I
their plastic frame work in the process.
!
(
4
Route one of the fan motor leads to terminal strip
AE
as shown. Cut off the excess lead length and remove
.
114" of insulation from the remaining lead.
1
(
4
Connect the prepared lead to lug
2
of terminal strip
I
AE
(NS).
(1
Connect the other fan motor lead to double lug AW
1
6-41, Cut to size, if necessary.