Page 53
I
!
I
Connect the wires from switches AN and
Z
as follows:
t
Wire
I
Coming
Connect
from
to
Lug
3,
Lug 2, terminal
switch
AN
J
strip AE 6-21.
Lug 1, Lug 1, circuit
switch
Z
I/
breaker AB (S-1
1.
Lug
2,
Lug 1, circuit
switch
Z/
breaker AA (S-1).
(fi
Prepare a 3" and 3-112" large black stranded wire by
cutting to length and removing 114" of insulation
from each end of each wire.
16
~onn&t one end of the 3" wire to lug 4 of terminal
strip AE (S-1). Connect the other end of this wire to
lug
2
of circuit breaker A6 (NS).
Use
the hole next to
the circuit breaker body.
Detail
4-13C
(4
Similarly, connect the 3-ID'' wire from lug 1 of
(4
Refer to Detail 4-13C and place the strain relief on the
terminal strip AE (S-1) to lug
2
of circuit breaker AA line cord just beyond the split portion of the cord, as
(NS).
shown.
Use
a pair of gas pliers to compress the strain
relief, and then insert
it
into hole AC from the outside
(
I,-$'
Connect a .O1
pF,
1.4 kV, disc capacitor from solder
of the chassis.
lug AD (NS) to lug 2 of circuit breaker AB (NS).
(4
Connect a .O1
pF,
1.4 kV, disc capacitor from solder
(
&
Connect the green line cord wire to solder lug AD
lug AD (NS) to lug 2 of circuit breaker AA (NS).
(S-3).
cord as shown. Remove 318" of insulation from the
J
(
Refer to Detail 4-13B and prepare the end of the line
(.
1
Connect one line cord conductor to lug 2 of circuit
breaker A6 (S-3).
end of each of the three conductors. Melt a
amount of solder on the end of each.
(d'
Connect the other line cord conductor to lug 2 of
circuit breaker AA 6-3).
G~N
Detail
4-13B