3–20  TNC 370 D  Mounting and Electrical Installation  July  02 
3.7.8  Switching Outputs 24 Vdc for the PLC 
 
Transistor outputs with current limiting 
 
 
Logic unit  PL 410 B/PL 405 B 
Min. output voltage for “1” signal  3 V below supply voltage 
Nominal operating current per output  0.125 A with simultaneity 
factor of 0.5 
1.2 A with simultaneity 
factor of 0.5; 
2 A with max. current 
consumption of 20 A 
 
·  Permissible load: resistive load; inductive load only with quenching diode parallel to the 
inductance. 
·  No more than one output may be shorted on the logic unit at any time. Short circuit of one 
output does not cause an overload. 
·  No more than half the PLC outputs may be driven at the same time (simultaneity factor 0.5). 
 
 
Address  No. of outputs  Device 
O0 to O30  31  Logic unit X41 (PLC output) 
O0 to O7    Logic unit X46 (machine operating panel)
O32 to O62  31  First PL 410 B 
O64 to O94  31  Second PL 410 B 
O48 to O62  15  PL 405 B 
 
X44 Power Supply for the outputs of the LE 
 
Terminal Assignment  PLC outputs 
1  +24 Vdc can be switched off via EMERGENCY 
STOP 
O0 to O23 
2  +24 Vdc cannot be switched off via EMERGENCY 
STOP 
O24 to O30 
3 0V   
 
Power Supply for the outputs on the PL 410 B/ PL 405 B 
 
Terminal  Assignment  1st PL 410 B 
Pl 405 B 
2nd PL 410 B 
X9 0 V     
X10  +24 Vdc power supply for logic and for control-is-ready signal 
X11  +24 Vdc power supply for outputs  O32 to O39  O64 to O71 
X12  +24 Vdc power supply for outputs  O40 to O47  O72 to O79 
X13  +24 Vdc power supply for outputs  O48 to O55  O80 to O87 
X14  +24 Vdc power supply for outputs  O56 to O62  O88 to O94 
 
For connecting the PL 410 B to the LE, see section 3.9.14.