July 02 Machine Parameters TNC 370 D 4–57
4.4 Positioning
Machine
parameter
Function and input Change via Reaction
MP1010.0-3 Rapid traverse
Input: 80 to 300 000 [mm/min]
PLC
MP1020.0-3 Manual feed rate
Input: 80 to 300 000 [mm/min]
PLC
MP1030.0-3 Positioning window
Input: 0. 001 to 2.000 [mm]
PLC
MP1040 Polarity of the nominal value voltage for the
positive traverse direction
Input: %xxxx
Bit 0 to 3 0 = not active
Axis X to 4 1 = active
Reset
MP1050.0-3 Analog voltage for rapid traverse
Input: 1.000 to 9.000 [V]
PLC
MP1060.0-3 Acceleration
Input: 0.001 to 20.000 [m/s
2
]
PLC
MP1070.0
Radial acceleration
Input: 0.001 to 20.000 [m/s
2
]
PLC
RUN
MP1070.1 Acceleration at contour transition elements
Input: 0.001 to 20.000 [m/s
2
]
PLC
RUN
MP1080.0-3 Integral factor
Input: 0 to 65 535
PLC
RUN
MP1090 Jerk limiting on the contour
Input: 0 to 1000 [m/s³]
0 = no jerk limiting (MP 1520 active)
1 to 1000 jerk limiting
MP1097.0-3 Axis-specific jerk limit
(active only with M112 and MP7415.1 bit 2)
Input: 1 to 1000 [m/s
3
]
Recommended input value 10 to 50
MP1099 Filter order for nominal position value filter
Input: 0 to 7
0 = no filter
1 to 7 filter order
Recommended input value 1 to 3
MP1110.0-3 Standstill monitoring
Input: 0.001 to 30.000 [mm]
PLC
MP1140.0-3 Movement monitor on
Input: 0.030 to 10.000 [V]
PLC
RUN