EasyManua.ls Logo

HEIDENHAIN TNC 370 D - Page 61

HEIDENHAIN TNC 370 D
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4–58 TNC 370 D Machine Parameters July 02
Machine
parameter
Function and input Change via Reaction
MP1150 Delay time for erasing the nominal velocity
value after an erasable error message
Positioning error <Axis> #
Input: 0.000 to 65.535 [s]
Recommended: 0
PLC
RUN
MP1220 Automatic cyclic offset adjustment
Input: 0 to 65 536 [s]
0 = no automatic adjustment
PLC
RUN
MP1320 Direction for traversing the reference marks
Input: %xxxx
Bit 0 to 3 0 = not active
Axis X to 4 1 = active
Reset
MP1330.0-3 Velocity when traversing the reference
marks
Input: 80 to 300 000 [mm/min]
PLC
RUN
MP1331.0-3 Velocity when leaving the reference end
position (only with MP1350=2)
Input: 80 to 500 [mm/min]
PLC
RUN
MP1340.0-3 Axis sequence when traversing the
reference marks
Input:
0 = No evaluation of the reference mark
1 = Axis X
2 = Axis Y
3 = Axis Z
4 = Axis 4
Reset
MP1350.0-3 Functional sequence when traversing the
reference marks
Input:
0 = linear encoder with distance-coded
reference marks (old routine)
1 = linear encoder with one reference mark
2 = special run (linear measurement via
ROD)
3 = linear encoder with distance-coded
reference marks (new routine)
Reset