TT 130 Triggering Touch Probe for Workpiece Measurement
X13 Touch Probe Input for Workpiece Measurement
Logic unit
D-sub terminal
(female) 9-pin
Assignment
1 Ready
2 0 V (U
N
)
4 +15 V ± 5% (U
P
)
7 +5 V ± 5% (U
P
)
8 Trigger signal
9
Trigger signal
1
3, 5, 6 Do not use
Housing External shield
1 Stylus at rest means logic level High
Adapter cable Id. Nr. 335 332 .. TT 130 Id. Nr. 296 537 06
D-sub
connector
(male) 9-pin
Coupling on
mounting base
(female) 6-pin
Connector
(male) 6-pin
1 Pink 6 6
2 White/Green 1 1 White
4 Gray 5 5
7 Brown/Green 2 2 Brown
8 Green 3 3 Green
9 Yellow 4 4 Yellow
Housing External shield Housing Housing External shield
3–30 TNC 370 D Mounting and Electrical Installation July 02