4 – 16 HEIDENHAIN Technical Manual TNC 426, TNC 430
MP331.0-8 Distance for the number of signal periods in MP332
Input: 0.0001 to 99.999 999 9 [mm] or [°]
PLC
REF
6 – 9
MP332.0-8 Number of signal periods for the distance in MP331
Input: 1 to 16 777 215
PLC
REF
6 – 9
MP334.0-8 Nominal increment between two fixed reference marks on
encoders with distance-coded reference marks
Input: 1 to 65 535
0: 1 000
280 474-09
PLC
6 – 9
MP340.0-8 Interpolation factor for external interpolation
Input: 0 to 99
0 = 1: No external interpolation
280 474-13
RESET
6 – 9
MP410 Assignment of axis keys IV and V
Input: Axis designation XYZABCUVWxyzabcuvw–
PLC
RESET
6 – 5
MP410.3 Axis key IV
MP410.4 Axis key V
MP420.0-8 Hirth coupling for axes 1 to 9
Input: 0: No Hirth coupling
1: Hirth coupling
PLC 6 – 398
MP430.0-8 Prescribed increment for Hirth coupling
Input: 0.0000 to 30.0000 [°]
PLC 6 – 398
MP710.1-8 Backlash compensation for axes 1 to 9
Input: -1.0000 to +1.0000 [mm] or [°]
PLC 6 – 36
MP711.0-8 Height of the spikes during circular movement (only analog)
for axes 1 to 9
Input: -1.0000 000 to +1.0000 999 [mm] (digital: 0)
PLC
RUN
6 – 47
MP712.0-8 Compensation value per control loop cycle time for axes
1 to 9
Input: 0.000 000 to 99.999 999 [mm] (digital: 0)
PLC
RUN
6 – 47
MP715.0-8 With M105, height of the spikes during circular movement
(only analog) for axes 1 to 9
Input: -1.0000 000 to +1.0000 999 [mm] (digital: 0)
PLC
RUN
6 – 47
MP716.0-8 With M105, compensation value per control loop cycle time
for axes 1 to 9
Input: 0.000 000 to 99.999 999 [mm] (digital: 0)
PLC
RUN
6 – 47
MP720.0-8 Linear axis error compensation for axes 1 to 9
Input: -1 000 to +1.000 [mm/m]
PLC 6 – 38
MP Function and input Software