December 2001 Touch Probe 6 – 373
Probe contact 7
77
7 In MP6531.x, enter the diameter (disk) or the edge length (cube) for the 
probe contact.
7
77
7 In MP6580, enter the coordinates of the probe contact center with respect 
to the machine datum. After calibration the NC internally saves the exact 
center of the probe contact.
7
77
7 If a PLC datum shift should be included in the tool measurement, set 
MP6500 bit 12 = 1.
For a cube it is enough to probe from one direction:
7
77
7 Set MP6500 bit 8 = 1.
7
77
7 With MP6500 bit 9, specify whether the basic rotation of the cube is 
measured automatically or whether it should be aligned to the axes 
mechanically. During automatic measurement, the edge of the touch probe 
is probed twice and the basic rotation is calculated. All subsequent probing 
is done automatically at a right angle to the touch probe edge.
7
77
7 With MP6500 bit 10, select how to pre-position to the starting point. If 
bit 10 = 1, then set bit 9 = 0.
MP6500 Tool measurement with TT 130
Format: %xxxxxxxxxxxxx
Input: Bit 7 – Reserved
Bit 8 – Probing routine
0: Probe contact is probed from several directions
1: Probe contact is probed from one direction
Bit 9 – Automatic measurement of the direction of the probe 
contact basic rotation (bit 8 = 1)
0: Basic rotation is not measured
1: Basic rotation of the probe element is automatically 
measured
Bit 10 – Probing routine (bit 8 = 1)
0: Pre-positioning to starting point in all three principal axes
1: Pre-positioning to starting point in the tool axis and in the axis 
of the probing direction (MP6505) (bit 9 = 0)
Bit 12 – Inclusion of the PLC datum shift
0: Do not include the PLC datum shift
1: Include the PLC datum shift
MP6531 Diameter or edge length of the TT 130 probe contact for 
3 traverse ranges
Input:  0.001 to 99.9999 [mm]
MP6531.0 Traverse range 1
MP6531.1 Traverse range 2
MP6531.2 Traverse range 3
MP6580.0-2 Coordinates of the TT 130 probe contact center with 
respect to the machine datum (traverse range 1)
Input:  -99 999.9999 to +99 999.9999 [mm]
MP6581.0-2 Coordinates of the TT 130 probe contact center with 
respect to the machine datum (traverse range 2)
Input:  -99 999.9999 to +99 999.9999 [mm]
MP6582.0-2 Coordinates of the TT 130 probe contact center with 
respect to the machine datum (traverse range 3)