December 2001 Commands 7 145
7.7.69 CALL MODULE (CM)
Syntax: CM (CALL MODULE)
Operands: Label (LBL)
Action:
After a CM command, the TNC calls the module that begins at the label that
you have entered. Modules are independent subroutines that must be ended
with the command EM. You can call modules as often as you wish from
different places in your program. CM interrupts a logic sequence.
Example:
See command CMF.
7.7.70 CALL MODULE IF LOGIC ACCUMULATOR = 1 (CMT)
Syntax: CMT (CALL MODULE IF TRUE)
Operands: Label (LBL)
Action:
The CMT command is a conditional module call. If the logic accumulator = 1,
the TNC calls the module that begins at the label that you have entered. If the
logic accumulator = 0, the TNC does not call the module. CMT interrupts a
logic sequence.
Example:
See command CMF.