December 2001 Commissioning 6 511
Higher current gain
beginning with the
rated speed
The counter EMF increases with increasing shaft speed. Therefore a higher
current gain is needed at higher shaft speeds:
7
77
7 With the integrated oscilloscope, record V (ACT RPM) and activate a shaft
speed greater than the rated speed.
If V (ACT RPM) pumps only at high shaft speeds, increase MP2403 until
the spindle runs quietly.
If V (ACT RPM) oscillates even at low shaft speeds, the problem lies with
resonance oscillations: You can compensate these oscillations in the
same way as for the axes, i.e., with the differential factor, low-pass filter
or the PT
2
element.