December 2001 List of Machine Parameters 4 – 45
MP6505 Probing direction for tool radius measurement for 3 traverse
ranges
Input: 0: Positive probing direction of the
angle reference axis (0° axis)
1: Positive probing direction in the +90° axis
2: Negative probing direction in the
angle reference axis (0° axis)
3: Negative probing direction in the +90° axis
PLC, CN123 6 – 372
MP6505.0 Traverse range 1
MP6505.1 Traverse range 2
MP6505.2 Traverse range 3
MP6507 Calculation of the probing feed rate
Input: 0: Calculation of the probing feed rate with
constant tolerance
1: Calculation of the probing feed rate with
variable tolerance
2: Constant probing feed rate
PLC, CN123 6 – 375
MP6510 Permissible measuring error for tool measurement with
rotating tool
Input: 0.002 to 0.999 [mm]
PLC, CN123 6 – 375
MP6510.0 First measurement error
MP6510.1 Second measurement error
MP6520 Probing feed rate for tool measurement with non-rotating
tool
Input: 1 to 3000 [mm/min]
PLC, CN123
RUN
6 – 376
MP6530 Distance from the tool end to the top of the probe contact
during tool radius measurement for 3 traverse ranges
Input: 0.001 to 99.9999 [mm]
PLC, CN123 6 – 372
MP6530.0 Traverse range 1
MP6530.1 Traverse range 2
MP6530.2 Traverse range 3
MP6531 Diameter or edge length of the TT 130 probe contact for 3
traverse ranges
Input: 0.001 to 99.9999 [mm]
PLC 6 – 373
MP6531.0 Traverse range 1
MP6531.1 Traverse range 2
MP6531.2 Traverse range 3
MP Function and input Software
version and
behavior
Page