6 388 HEIDENHAIN Technical Manual TNC 426, TNC 430
Example:
MP4030 Assignment of physical to logical PL
As of software version:280 476-01
Input: 0: First logical PL
1: Second logical PL
2: Third logical PL
3: Fourth logical PL
MP4030.0 First physical PL
MP4030.1 Second physical PL
MP4030.2 Third physical PL
MP4030.3 Fourth physical PL
LE
PL 2
I192 to
I255
O64 to
O94
PL 1
I64 to
I127
O32 to
O62
PL 3
I256 to
I319
O128 to
O158
PL 4
I320 to
I383
O160 to
O190
LE
PL 3
I192 to
I255
O64 to
O94
PL 1
I64 to
I127
O32 to
O62
PL 4
I256 to
I319
O128 to
O158
CAUTION
PLC program
must be
changed!
or
MP4030.0 = 0 : 1st physical PL = 1st logical PL
MP4030.1 = 2 : 2nd physical PL = 3rd logical PL
MP4030.2 = 3 : 3rd physical PL = 4th logical PL
LE
PL 3
I256 to
I319
O128 to
O158
PL 1
I64 to
I127
O32 to
O62
PL 4
I320 to
I383
O160 to
O190
CAUTION
PLC program
need not be
changed!