6 – 396 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9036 Writing status information
The information to be overwritten is designated with a transferred number.
Call:
PS B/W/D/K <Number of the status information>
PS B/W7D/K <Value to be written>
CM 9036
PL B/W/D <Error code>
0: Status written
1: Incorrect status code
2: Transferred value out of range
3: Input disabled
Error recognition:
Number of the
status information
Function Value
0 to 6 See
”Handwheel”
10 Jog increment
limiting
0.0001 to 50 mm:
Jog increment limiting
–1; < –2; > 50:
Cancellation of the jog increment
limitation and activation of the jog
increment entered last
–2:
Cancellation of the jog increment
limitation and activation of the
minimum from jog increment
entered last and last limitation
11 to 19 See
“Handwheel”
Marker Value Meaning
M4203 0 Status information was written
1 Error code in W1022
W1022 1 Transferred value out of range
2 Incorrect number of the status information
6 Input disabled