December 2001 Software Releases 2 – 67
NC software
280 476-07 (export
version 280 477-07)
Release: 02/00
Improvements:
n MP812: Software limit switches also with M94, modulo display and
encoders with EnDat interface
n MP2606: Influence following error during the jerk phase
n MP3030: Zero spindle speed when switching to another gear range
n MP6500: Tool measurement with stationary spindle
n MP7261: Pockets in tool magazines 1 through 4
n MP7267: Position of the comment from the tool table in the pocket table
n MP7620: Feed-rate smoothing
n MP7683: Display of pallet table and NC program
n Up to 4 tool magazines may be managed in the pocket table.
n Encoders with EnDat interface can be used as position encoders for rotary
axes.
n Monitoring of the number of grating periods between the reference end
position and the first reference mark
n In a tilted working plane in Manual mode, more than one axis can be moved
simultaneously, and the start key can be used to traverse the reference
marks.
n In the WAIT column of the table of M-function macros, you can determine
if the NC should wait for acknowledgement from the PLC.
n With the aid of the “machine parameter subfile” column in the assignment
table of the tilting-axis geometry description, a function for changing milling
heads can be created.
n 16 strings
n After the drive is switched on, the control waits 2 s for the “ready” signal.
n Module 9097: Error codes 9 (Error in the MPFILE column), 10 (Error in the
MP7500 column) and 11 (Error in the machine parameter subfile) added
n Module 9031: Find the number of an entry in the pocket table
n Module 9032: Look for a free pocket in the tool magazine
n Module 9036: Switch tools between tool magazines
n Cylindrical surface interpolation in a tilted working plane
n SUPPORT soft key for remote diagnosis with TeleService
n A comment can be entered in the DOC column of the datum tables.
n M142: Delete modal program information
n M143: Delete programmed basic rotation
n Display “TNC 426/430 x” when control is switched on
n M109 or M110 are automatically cancelled when an OEM cycle ends or is
cancelled.
NC software
280 476-07 (export
version 280 477-07)
Release: 02/00
Improvements:
n MP812: Software limit switches also with M94, modulo display and
encoders with EnDat interface