EasyManua.ls Logo

HEIDENHAIN TNC 430 PA - Page 804

HEIDENHAIN TNC 430 PA
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 474 HEIDENHAIN Technical Manual TNC 426, TNC 430
7
77
7 When the current gain is properly adjusted, press the STORE MP2400.x soft
key to transfer the optimized value directly into the machine parameter.
7
77
7 Press the END key to exit the I CONTROL mode again.
MP2400 too large
MP2400 optimum
Max. 600 µs

Table of Contents

Other manuals for HEIDENHAIN TNC 430 PA

Related product manuals