7 – 66 HEIDENHAIN Technical Manual TNC 426, TNC 430
567 L M4002 49 L NP_M4002_S_analog_0_V
568 S M3968 50 S ML_servo_activ_poweron
569 L M4005 51 L PN_M4005_S_M03_analog_volt_status
570 O M4006 52 O PN_M4006_S_M04_analog_volt_status
571 ON M4002 53 ON NP_M4002_S_analog_0_V
572 O M4130 54 O PN_M4130_Strobe_PLC_pos_spindle
573 A M3968 55 A ML_servo_activ_poweron
574 S O15 56 S O_Spindle_servo_enable
57
576 L M3995 58 L MG_spindle_off_M05
577 O M3993 59 O MG_T_I_N_supervision
578 ON I3 60 ON I_not_emergency_stop
579 ON I3 61 ON I_servo_ready_1
580 ON I3 62 ON I_servo_ready_2
581 R O15 63 R O_Spindle_servo_enable
64
583 LN M4072 65 LN NP_M4072_strobe_M_function
584 = T7 66 = TS_M_func_delay
67
586 L M4072 68 L NP_M4072_strobe_M_function
587 A M4001 69 A NP_M4001_S_analog_not_in_ramp
588 AN M4130 70 AN PN_M4130_Strobe_PLC_pos_spindle
589 AN T7 71 AN TS_M_func_delay
590 AN T55 72 AN TR_M_func_delay
591 AN M4805 73 AN PN_error_not_used_M_function
592 = M4092 74 = PN_M4092_quit_M_function
593 EM 75 EM
76
K0 77 #define KL_angle_spindle_pos K+0
K100000 78 #define KL_RPM_spindle_pos K+100000
K0 79 #define KL_direction_spindle_pos K+0
80
596 LBL M19_START_SPI_PO 81 LBL M19_start_spi_pos
597 PS K0 82 PS KL_angle_spindle_pos
598 PS K100000 83 PS KL_RPM_spindle_pos
599 PS K0 84 PS KL_direction_spindle_pos
600 CM 9171 85 CM 9171
601 L M4203 86 L NP_M4203_error_Modul_9xxx
602 S M4806 87 S PN_error_9171_Spi_Pos
603 EM 88 EM
________________________________ Local Symbols _______________________________
KL_ANGLE_SPINDLE_POS : 77 K0
PS:597
KL_DIRECTION_SPINDLE_POS : 79 K0
PS:599
KL_RPM_SPINDLE_POS : 78 K100000
PS:598
________________________________Static Symbols _______________________________
ML_SERVO_ACTIV_POWERON : 9 M3968
S:568 A:573
ML_SPI_POS_START : 8 M3969
AN:531 S:533 R:537
________________________________ Local Labels ________________________________
9171 : 9171
85
M19_START_SPI_PO : 81
14
PLC program example