3 Sensors
10 KRONOS 20
3 Sensors
3.1 Overview Table
Sensor Speed
Intake Mani-
fold Pressure
Intake Manifold
Temperature
λ Sensor
(optional)
HZM name IA .. P/T-S-01 LSM 11
Connection
SV 6-IA-2K
2 pin
Pressure sensor connector 4 pins
Measuring
methods
inductive,
active
piezo resistance,
active
NTC, passive electrochemical
Measuring range 50..9,000 Hz 0.2..3.0 bar abs. -40 to +130°C 1.00..2.00
Power supply
range
4.5..5.5 V DC 12..13 V AC/DC
Output signal
range
0..10 V AC 0.3..4.8 V 0..50 kOhm 0..900 mV
Operating tem-
perature range
-8 to +120°C -40 to + 130°C up to + 800°C
In order to allow sufficient flexibility and comparability of sensors, the min./max. values of
pressure sensors and temperature sensors are programmable.
3.2 Speed Pickup IA…
3.2.1 Technical Data
Operating principle inductive sensor
Distance from measuring wheel 0.5 to 0.8 mm
Output 0 V to 12 V AC
Signal type sine (depending from tooth shape)
Resistance approx. 52 Ohm
Temperature range
housing -8°C to +120°C
cable -5°C to +80°C
Protection grade IP 55
Vibration < 10g, 10 to 100 Hz
Shock < 50g, 11 ms half sine
Connector used SV 6 - IA - 2K (EDV-No: 010-02-170-00)