EasyManua.ls Logo

Heinzmann KRONOS 20 - 4 Control Unit KRONOS 20; Technical Data; General

Heinzmann KRONOS 20
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Control Unit KRONOS 20
18 KRONOS 20
4 Control Unit KRONOS 20
4.1 Technical Data
4.1.1 General
Power supply 12 V DC or 24 V DC
Min. voltage 10 V DC
Max. voltage 32 V DC
Residual ripple max. 10 % maximum at 100 Hz
Current consumption max. 1 A
Admissible voltage drop
at max. power consumption max. 10 % at control unit
Fuse 6 A
Storage temperature -40°C to +85°C
Operating temperature -40°C to +80°C
Air humidity up to 98 % at 55 °C
Vibration max. 2 mm at 10..20 Hz
max. 0.24 mm at 21..63 Hz
max. 9 g at 64..2000 Hz
Shock 50 g, 11 ms, half sine
Protection grade IP 00
Isolation resistance > 1 MOhm at 48 V DC
Weight approx. 0.5 kg
EMC 89/336/EEC and 95/54/EEC

Table of Contents