14 Parameter Description
KRONOS 20 77
14.3 List 2: Measurements
No. Name Signification
2000 Speed
Level: 1
Range: 0..4000 1/min
Page(s): 55
Current speed value
2003 SpeedPickUpValue
Level: 4
Range: 0..4000 1/min
Page(s):
Unfiltered speed signal from speed pickup
2050 SpeedVariance
Level: 4
Range: 0..65,535
Page(s):
Actual value of speed variance
2250 EngineStartCounter
Level: 1
Range: 0..65535
Page(s):
Engine start counter
2302 StepperPos
Level: 4
Range: 0..4000 steps
Page(s):
Actual stepper position
2331 StepperPosAbsMax
Level: 4
Range: 0..4000 steps
Page(s):
Absolute max. position of stepper motor (depending on
E-LES type)
2332 StepperPosSetpoint
Level: 4
Range: 0..4000 steps
Page(s):
Calculated setpoint for stepper motor
2333 StepperPosSetpSelect
Level: 4
Range: 0..4000 steps
Page(s):
Actual setpoint for stepper motor
2810 SwitchEngineStop
Level: 1
Range: 0..1
Page(s):
Switch position "Engine stop"
2828 SwitchErrorReset
Level: 1
Range: 0..1
Page(s):
Switch position "Reset errors "
2851 DigitalOut1
Level: 6
Range: 0..1
Page(s):
Condition of digital output 1 (stepper motor control)