EasyManua.ls Logo

Heinzmann KRONOS 20 - Page 81

Heinzmann KRONOS 20
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Parameter Description
KRONOS 20 73
No. Name Signification
1400 ClosedLpPowerMinRate
Level: 4
Range: 0..100 %
Page(s):
Output power switch point for mode change from Open
loop mode to Closed loop mode
1401 ClosedLoopGov:I
Level: 4
Range: 0..100 %
Page(s):
Stability value for lambda control in Closed loop mode
1410 EngineDisplacement
Level: 4
Range: 0..100 dm³
Page(s):
Engine Displacement
1411 EngineRatedPower
Level: 4
Range: 0..2500 kW
Page(s):
Engine rated power
1412 VolEfficiencyConst
Level: 4
Range: 0,5..1
Page(s):
Constant value for volumetric efficiency of the engine
1413 MechEfficiencyConst
Level: 4
Range: 0,1..0,5
Page(s):
Constant value for mechanical efficiency of the engine
1420 ThroatArea
Level: 4
Range: 300..30000 mm²
Page(s):
Throat area of gas mixer insert
1421 GasMeteringHolesArea
Level: 4
Range: 100..10000 mm²
Page(s):
Overall area of gas holes in the gas mixer insert
1422 RefMeteringHolesArea
Level: 4
Range: 100..10000 mm²
Page(s):
Overall area of reference gas holes in the gas mixer
insert. Normally the same as in 1421
1423 HolesCorrFactor
Level: 4
Range: 1..2
Page(s):
Correction factor for geometry of gas holes (depends on
actual gas mixer insert)
1424 VenturiEfficiency
Level: 4
Range: 0,5..1
Page(s):
Correction factor for efficiency of gas mixer insert ho-
les (depends on actual gas mixer insert)

Table of Contents