EasyManua.ls Logo

Heinzmann KRONOS 20 - Page 83

Heinzmann KRONOS 20
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Parameter Description
KRONOS 20 75
No. Name Signification
1531 AnalogIn3_RefHigh
Level: 4
Range: 0..22,7 mA
Page(s):
High reference value of analogue input 3
1532 AnalogIn3_ErrorLow
Level: 4
Range: 0..22,7 mA
Page(s):
Low error limit of analogue input 3
1533 AnalogIn3_ErrorHigh
Level: 4
Range: 0..22,7 mA
Page(s):
High error limit of analogue input 3
1534 AnalogIn3_Filter
Level: 4
Range: 1..255
Page(s):
Filter value of analogue input 3
1540 AnalogIn4_RefLow
Level: 4
Range: 0..5 V
Page(s):
Low reference value of analogue input 4.
Standard for manifold pressure. Here set for 0..5 V
1541 AnalogIn4_RefHigh
Level: 4
Range: 0..5 V
Page(s):
High reference value of analogue input 4
1542 AnalogIn4_ErrorLow
Level: 4
Range: 0..5 V
Page(s):
Low error limit of analogue input 4
1543 AnalogIn4_ErrorHigh
Level: 4
Range: 0..5 V
Page(s):
High error limit of analogue input 4
1544 AnalogIn4_Filter
Level: 4
Range: 1..255
Page(s):
Filter value of analogue input 4
1552 TempIn_ErrorLow
Level: 4
Range: 0..65472
Page(s):
Low error limit of temperature input
Standard manifold temperature
1553 TempIn_ErrorHigh
Level: 4
Range: 0..65472
Page(s):
High error limit of temperature input

Table of Contents