14 Parameter Description
80 KRONOS 20
No. Name Signification
3080 ErrDisplay
Level: 1
Range: 0..1
Page(s):
Error indication for control display
3081 Err5V_Ref
Level: 1
Range: 0..1
Page(s):
Error indication for 5 V reference voltage
3085 ErrVoltage
Level: 1
Range: 0..1
Page(s):
Error indication for power supply voltage
3090 ErrData
Level: 1
Range: 0..1
Page(s):
Error reported during parameter loady from EE-PROM
3092 ErrConfiguration
Level: 1
Range: 0..1
Page(s):
Error indication for software configuration
3093 ErrStack
Level: 1
Range: 0..1
Page(s):
Error indication for stack overflow
3094 ErrIntern
Level: 1
Range: 0..1
Page(s):
Error indication for internal software fault
3099 EEPROMErrorCode
Level: 6
Range: 0000..FFFF Hex
Page(s):
Error code during loading of parameters from EE-
PROM
3101 SErrPickUp
Level: 1
Range: 0..255
Page(s):
Sentinel for the occurrence of 3001 ErrPickUp
3104 SErrOverSpeed
Level: 1
Range: 0..255
Page(s):
Sentinel for the occurrence of 3004 ErrOverSpeed
3117 SErrManifoldPressure
Level: 1
Range: 0..255
Page(s):
Sentinel for the occurrence of
3017 ErrManifoldPressure