11 Parameter description
Positioner DC 6-06 79
3007 ErrFuelSetpAna
Level: 1
Range: 0/1
Page(s): 25, 64
Error displa
y of the analogue setpoint generator
3009 ErrFuelSetpPWMIn1
Level: 1
Range: 0/1
Page(s): 25, 64
Error displa
y of the PWM setpoint generator at PWM
input 1
3011 ErrFuelSetpPWMIn3
Level: 1
Range: 0/1
Page(s): 25, 64
Error displa
y of the PWM setpoint generator at PWM
input 3
3050 ErrFeedback
Level: 1
Range: 0/1
Page(s): 63, 64
Error in the
measured value of the actuator feedback
3053 ErrActuatorDiff
Level: 1
Range: 0/1
Page(s): 65
Excessive dif
ference between control path setpoint and
actual-value
3056 ErrFeedbackRef
Level: 1
Range: 0/1
Page(s): 63, 65
Error in the referenc
e value of the actuator feedback
3059 ErrFeedbackAdjust
Level: 1
Range: 0/1
Page(s): 50, 63, 66
Error in the a
uto adjust or when entering the reference
values of the feedback
3060 ErrAmplifier
Level: 1
Range: 0/1
Page(s): 63, 66
Am
plifier error
3075 ErrClearFlash
Level: 1
Range: 0/1
Page(s): 27, 63, 66
Error displa
y when clearing the read-only memory
(displayed in the bootloader)
3076 ErrParamStore
Level: 1
Range: 0/1
Page(s): 27, 63, 67
Error displa
y when programming the read-only memory
3077 ErrProgramTest
Level: 1
Range: 0/1
Page(s): 27, 63, 67
Error displa
y when checking the checksum of the
firmware program

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann PANDAROS DC 6-06 and is the answer not in the manual?

Heinzmann PANDAROS DC 6-06 Specifications

General IconGeneral
BrandHeinzmann
ModelPANDAROS DC 6-06
CategoryValve Positioners
LanguageEnglish