10
Fault reports and their correction
28 Betriebsanleitung_firestar_18-40_Lambda_Englisch_V1.6
Other possible faults
Cause
Corrective actions
Boiler capacity too low
The calorific value of the used fuel
is too low. The moisture of the
fuel is higher than 25%.
Use required fuel at required
moisture
The operating conditions were not
observed.
Call for service
The exhaust gas collector or the
exhaust system is leaking.
Check test openings and
exhaust ports and if
necessary seal them
The boiler capacity is for the
application too small.
Call for service
Supply air is missing.
Provide for sufficient fresh air
Call for Service
The door seals are defect.
Call for service
The exhaust gas collector and the
combustion chamber are dirty, so
very little heat transfer is
available.
Clean the boiler
Incorrect air intake
Check the tightness of the
test openings and doors
Dust deposits on or near the
cleaning cap.
The cleaning cap is not closed
correctly or the seals are leaking.
Close the cleaning cap
correctly
Call for service
Excessively condensate is
formed in the filling room of the
boiler.
Excessive boiler performance at
low heat consumption (induced
draft fan does not rotate).
Insert less fuel
Correct inadequate heat
consumption of the heating
system
The fuel is incorrect or too moist.
Use required fuel
The boiler water temperature is
too low.
Call for service
Induced draft fan does not rotate
or is too loud.
Attention!
A fan which is not in operation
leads to incomplete combustion
and tar deposits.
Only when fan is not in operation:
The maximum boiler temperature
or exhaust temperature is
reached.
No fault! Boiler is operating
properly. Induced draft fan
starts when you open the
filling door. Too much fuel.
Blower motor is defect.
Call for service
The door switch is in the wrong
position or defective.
Call for service