4G_2G DTU Products Function
http://www.iotworkshop.com - 38 -
2.4.2.14. AT+Z
Function: Hard restart.
Format:
AT+Z<CR>
+ok<CR><LF><CR><LF>
The IO control state is initialized.
2.4.2.15. AT+UART
Function: Set/query the serial port operation, and the settings will take effect after reset.
Format:
Query Operation:
AT+UART=<id><CR>
+ok=<id,baudrate,data_bits,stop_bit,parity,flowctrl><CR><LF><CR><LF>
Set Operation:
AT+UART=<id,baudrate,data_bits,stop_bit,parity,flowctrl><CR>
+ok<CR><LF><CR><LF>
Parameter:
idSerial port number
1: Port 1
2: Port 2 (G10, G11, G12 support)
baudrate: Baud rate, default115200】。
600, 1200,2400,4800,9600,19200,38400,57600,115200,230400,460800
data_bits: Date bit, default8
7,8
stop_bits: Stop bit, default1
1,2
parity: Check bit, defaultNONE
NONE
EVEN
ODD
flowctrl: Hardware flow control (CTSRTS), only serial port 1 supports hard flow control,
defaultNFC
NFC: No hardware flow control
FC: Hardware flow control (EG1X, EG43 dont support)
HD: Half-duplex mode for RS485.
2.4.2.16. AT+UARTTM
Function: Set/Query the Two-Frame Time Interval When the Serial Port Receives Data.
Format:
Query Operation:
AT+UARTTM=<id><CR>
+ok=<id><interval><CR><LF><CR><LF>
Set Operation:
AT+UARTTM=<id><interval><CR>
+ok<CR><LF><CR><LF>
Parameter:
idSerial port number
1: Port 1
2: Port 2 (G10, G11, G12 support)
interval: Serial port division interval, default 200ms, range 10~1000ms
2.4.2.17. AT+MODBUS
Function: Set/query Modbus TCP to Modbus RTU function.
Format: