2. Wiring and connection
2-7
AC SERVO operating
device
FDA7015/
FDA7015B
FDA7020/
FDA7020B
FDA7030/
FDA7030B
FDA7045
Wire thickness AWG #12(3.5mm
2
) AWG #10 (5.5mm
2
)
Open/close device GMC-40(35A) GMC-50(50A) level product
Breaker
ABS33b
(10A)
ABS33b
(20A)
ABS33b (30A)
Level product
Noise filter
NFZ-4030SG
(30A)
NFZ-4040SG
(40A)
External regenerated
resistance
250W
25Ω
(External
diagram A)
250W 25Ω parallel 2 units
(External diagram A)
Open/close device and Breaker : LS Industrial Systems, http://www.lsis.biz
Noise filter : Samil Components, http://www.samilemc.com
M4
∮4.3
Length
:300
220
239
30
60
<External view A>