Chapter 3 I/O Wiring
3.1 Input Signal
The device's LineIn 0/1/2 is opto-isolated input, and their internal circuit is as follows.
Note
The input voltage ranges from 5 VDC to 30 VDC.
The maximum current is 5 mA.
Figure 3-1 Internal Circuit of Input Signal
3.2 Output Signal
The device's LineOut 0/1/2 is opto-isolated output, and their internal circuit is as follows.
Note
The input voltage ranges from 5 VDC to 30 VDC.
The maximum current is 200 mA.
Do not directly connect with inductive load (e.g. DC motor, etc.) when outputting.