ID6000 Series Smart Code Reader User Manual
33
Figure 7-13 Set and Execute Counter Trigger Mode
Set and Execute TCP Trigger Mode
TCP start specifies the TCP server as the source for the trigger signal. When the server receives the
specified string text, the trigger signal will be outputted.
Click I/O Control Settings Input Trigger Mode, select On as Trigger Mode and select TCP
Start as Trigger Source.
Set Trigger Delay, Tcp Trigger Port, and Tcp Start Trigger Text according to actual demands.
Figure 7-14 Set and Execute TCP Trigger Mode
Set and Execute UDP Trigger Mode
UDP start specifies the UDP server as the source for the trigger signal. When the server receives
the specified string text, the trigger signal will be outputted.
Click I/O Control Settings Input Trigger Mode, select On as Trigger Mode and select UDP
Start as Trigger Source.
Set Trigger Delay, Udp Trigger Port, and Udp Start Trigger Text according to actual demands.