Video Intercom Door Station·User Manual
52
Device ID Configuration
Steps:
1. Click ID Configuration to enter device ID configuration interface.
Door Station
Outer Door Station
2. Select the device type from the drop-down list, and set the corresponding
information.
3. Click Save to enable the device number configuration.
For main door station (D series or V series), the serial No. is 0.
For sub door station (D series or V series), the serial No. is higher than 0. Serial No.
ranges from 1 to 99.
For each villa or building, at least one main door station (D series or V series) should
be configured, and sub door stations (D series or V series) can be customized.
For one main door station (D series or V series), at most 8 sub door stations can be
customized.
Select doorphone as device type, and the serial No. is not necessary to configure.
Please utilize the doorphone along with the main door station (V Series or D Series).
Time Parameters
1. Click Time Parameters to enter time parameters settings interface.
2. Configure the maximum ring duration, maximum live view time, and call forwarding
time.
3. Click Save.
For door station, maximum speaking time and maximum message time should be
configured. Maximum speaking time varies from 90s to 120s, and maximum message
time varies from 30s to 60s.

Table of Contents

Other manuals for HIKVISION D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION D Series and is the answer not in the manual?

HIKVISION D Series Specifications

General IconGeneral
BrandHIKVISION
ModelD Series
CategoryIntercom System
LanguageEnglish

Related product manuals