Click the button to enable quick setup of image/video related 
parameters, including Specify Display, OSD and Video/Audio parameters. 
For detailed configuration, refer to Section 0 Smooth Streaming 
Purpose: 
This function is used to view the live view smoothly via the client 
software or Web Browser when the network is unstable or high 
quality of video is required. 
Notes: 
Supported services vary according to camera models. 
Before you start: 
Add the device to your client software and enable the NPQ protocol 
for live view via the client. 
Steps: 
1.  Enter the Smooth Streaming interface: 
Configuration  >  Network  >  Advanced  Settings  >  Smooth 
Streaming 
2.  Select the Stream Type. 
3.  Check Enable Smooth Streaming. 
4.  Select  the  mode  of  smooth streaming.  There  are  three  modes 
selectable: Auto, Resolution Priority, and Error Correction. 
  Auto:  The  resolution  and  bitrate  will  be  adjusted 
automatically, the upper limits of which will not exceed the 
values  you  set  on  Video  page.  Go  to  Configuration  > 
Video/Audio  >  Video  page,  set  the  Resolution  and  Max. 
Bitrate before you enable smooth streaming function. 
  Resolution  Priority:  The  resolution  stays  the  same  as  the 
set  value  in  Video  page,  and  the  bitrate  will  be  adjusted 
automatically. Go to Configuration > Video/Audio > Video 
page,  set  the  Max.  Bitrate  before  you  enable  smooth 
streaming function. 
  Error Correction: The  resolution and bitrate stay the same 
as  the  set  values  in  Video  page.  This  mode  is  used  to 
correct  the  data  error  during  transmission.  You  can 
configure  the  error  correction  proportion  within  range  of 
0-100.  When  the  proportion  is  0,  the  data  error  will  be 
corrected by  data  retransmission.  When  the  proportion  is 
higher  than  0,  the  error  data  will  be  recovered  via 
redundant data that is added to the stream. The higher the 
value  is,  the  more  redundant  date  will  be  generated,  and 
the  larger  bandwidth  is  required.  When  the  proportion  is 
100,  the  redundant  data  will  be  as  large  as  the  original 
data. 
Note:  Be  sure  the  bandwidth  is  sufficient  in  Error 
Correction mode. 
5.  Click  to save the settings. 
HTTP Listening 
Alarm  information  can  be  sent  to  destination  IP  or  Host  via  HTTP