User Manual of Network Traffic Camera revise 
50 
 
Recognition are selectable. 
  Small-Size  Plate  Recognition:  Select  it  when  the  character  height  of  the 
license plate is in the range of 20 to 30 pixels. 
  Large-Size  Plate  Recognition:  Select  it  when  the  character  height  of  the 
license plate is in the range of 30 to 40 pixels. 
11.2 Configuring Flash Light Parameters 
Steps: 
1.  Go to Configuration > Device Configuration > Capture Parameters > Flash 
Light Parameters. 
2.  Select a tab corresponded with the flash light control port. 
The camera supports IO:1, IO: 2 and IO:3.   
IO:1 is the built-in flash light. IO:2 and IO: 3 are for extra flash lights.   
 
 
Figure 11-2 Flash Light Parameters Configuration 
3.  Select IO Output Mode. Constant Light Mode is available. 
  Constant Light Mode 
1)  Input Duty Ratio. It controls the power level of the flash light. 0 means 
light off, 70 means full-power. 
2)  Set  light  on/off  control  mode.  The  on/off  status  can  be  controlled 
automatically or on schedule. 
Auto: Check Control Constant Light By Brightness. Set the brightness