3.3.6 Other Hardware Setting
Adjust the LCD brightness as follows:
To brighten:
Hold down the SET button and press the
MONITOR button.
To darken:
Hold down the SET button and press the
FUNCTION button.
The calendar and clock are set by Hitachi prior to
delivery. To reset the calendar and clock, please con-
tact the local Hitachi distributor.
The following is a table of contents that can be set by
the LCD monitor and digital monitor (next section).
󱦯 Initial Setting
The language of the display can be switched to
Japanese, English or Chinese by the dip switch on the
back of the LCD monitor board. If the language needs
to be changed, consult with your dealer or the Hitachi
Service Station given on the rear cover.
󱦵 3-Language Display Switch
󱦱 Brightness Adjusting
󱦳 Digital Monitor Operation Classification
Bit
1234 8
Japanese setting
OFF OFF
Not used
English setting
ON OFF
Chinese setting
OFF ON
Test mode
ON ON
Power must be turned off before changing setting.
Function Item
LCD monitor oper-
ation
Digital monitor
(F mode)
Remarks
Operation Mode
Screen
Mode
○ F000
Dual, backup, etc.
Dual operation time
Switch conditions
Switch time
Backup pressure
Differential pressure
Unload
Differential pressure
Dual operation remaining time
△(AUTO change)
Speed control mode
○(Factory set)
V type only
Capacity Control
Screen
Type (Left: Capacity control)
○ F019
Example: I type (load/unload type)
Type (Center: Setting type)
○ F018
Example: Setting 1
Type (Right: Function)
Option (not supported)
Pressure loss
Option (not supported)
Total piping capacity
Option (not supported)
Control pressure
○ F022
Setting 1, Setting 2
Recovery pressure
○ F022
Setting 1, Setting 2
Target pressure
○ F022
Pressure differential
Time limit
○(Factory set)
Energy saving mode decision time
Setting 2: Use time
Scheduled Operation
Screen
Contents
Function switch
Start/stop time
Data measurement time
Operation data measurement
Other Settings
Compressor No. setting
○ F001
Instantaneous power interruption (IPI) setting
○ F002
Remote operation setting
○ F005
Dryer operation setting
○ F008
AUTO operation setting
○ F011
Energy saving mode setting
Display switch button operation
Reset
Shutdown/alarm reset
Reset button operation
Load count reset
Remote + display switch button
Maintenance reset
○−
Set button 7 sec. ON
Shutdown/alarm history clear
○ F041
22
3. OPERATING THE DSP [How to Use the Liquid Crystal Display (LCD)]

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi DSP-160V6WN and is the answer not in the manual?

Hitachi DSP-160V6WN Specifications

General IconGeneral
BrandHitachi
ModelDSP-160V6WN
CategoryAir Compressor
LanguageEnglish

Related product manuals