Item Specification Comments
Subnet mask Supported N/A
Gateway address Supported N/A
DHCP N/A N/A
DNS N/A N/A
Ping (ICMP ECHO) Transmit,
Receive
Supported N/A
IPsec
2
N/A N/A
TCP port number 3260 Changeable among 1 to
65,535. Observe the
follo
wing if changing
values:
â– 
The setting of the
corresponding host
should also be changed
to log in the new port
number.
â– 
The new port number
might conî µict with other
network communication
or be î ´ltered on some
network equipment,
preventing the storage
system from
communicating through
the new port number.
iSCSI name Both iqn
3
and eui
4
types
are supported
The unique iqn value is
automatically set when a
target is made. iSCSI name
is conî ´gurable.
Error recovery level 0 (zero) Error recovery by retrying
from host. Does not
support Level 1 and Level
2.
Header digest Supported Detects header error or
data error with iSCSI
communication. The
storage system follows the
host's digest setting. If
digest is enabled, the
performance degrades.
iSCSI speciî ´cations
Appendix F: Data and power cables
Hitachi Virtual Storage Platform G200 Hardware Reference Guide 113