Battery speciî ´cations
Storage system intake
temperature CBSS CBSL
Up to 75.2º F (24º C) 5 years 5 years
Up to 86º F (30º C) 5 years 4 years
Up to 93.2º (34º C) 4 years 3 years
Up to 104º (40º C) 3 years 2 years
RAID speciî ´cations
D: Data drive, P: Parity drive.
Although the stor
age system with a conî ´guration of RAID 1, RAID 5, or RAID 6 provides
data reliability enhanced by redundancy, there is a chance that user data could be lost
due to an unexpected host, storage system hardware, or software failure. Therefore,
users are requested to back up all data.
Item Drive tray
RAID Level SAS, SAS 7.2k, î µash drives mounted
RAID 1 2D+2D, 4D+4D
RAID 5 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID 6 6D+2P, 12D+2P, 14D+2P
Item Specification
Maximum number of parity groups 88
Maximum volume size 3 TB (or 4 TB when using the LDEVs of
other stor
age systems)
Maximum volumes/host groups and iSCSI
targets
2,048
Maximum volumes/parity groups 2,048
VSP G200 mechanical speciî ´cations (A
C power supply model)
Appendix A: Mechanical speciî ´cations for VSP G200
Hitachi Virtual Storage Platform G200 Hardware Reference Guide 74