EasyManua.ls Logo

Hitachi HISCREW V PLUS NEXT Series - Daily Operation and Shutdown; Running the Compressor Daily; Daily Compressor Stop Procedure

Hitachi HISCREW V PLUS NEXT Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.5.3 Operation
3.5.4 Stop
②③
RUNNING CONTROL RUNNING MODE
ALARM
警 报
运行状况
故 障
LOAD
SHUTDOWN
REMOTE
负 载
远 程
电 源
POWER
自动启动
AUTO START
停 机
STOP
开 机
START
存 储
远 程
REMOTE
显示转换
扩展模式
STR
功 能
FUNC
重新设定
RESET
SELECT/WIDE
运行管理
④①
Power
Supply
RUNNING CONTROL RUNNING MODE
ALARM
警 报
运行状况
故 障
LOAD
SHUTDOWN
REMOTE
负 载
远 程
电 源
POWER
自动启动
AUTO START
停 机
STOP
开 机
START
存 储
远 程
REMOTE
显示转换
扩展模式
STR
功 能
FUNC
重新设定
RESET
SELECT/WIDE
运行管理
Press the STOP button.
The compressor stops.
Open the front door and make sure the oil separator
tank internal pressure gauge reads 0 MPa.
(It returns to 0 for about 1 or 2 minutes after stop.)
Fully close the valve on discharge side.
Disconnect the power.
The instrument panel POWER light goes off after
about 10 seconds.
Press the START button.
Make sure that the air compressor starts.
Make sure that the oil level during operation is kept
within the range between the red lines.
If it is below the lower line, follow the procedure on
page 21 and replenish the genuine synthetic oil
(NEW
HI
SCREW OIL NEXT).
Digital monitor displays discharge air pressure by
0.01MPa.
Press the SELECT button on the instrument panel
and check if the discharge air temperature is within
the range between 65 and 100 .
(After temperature stabled)
Discharge air pressure displayed on the instrument panel
is unit exit side pressure (minimum pressure / check valve
downflow side pressure). If there is pressure remaining in
the air tank, the gauge does not read 0 MPa.
The oil separator tank internal pressure gauge (minimum
pressure / check valve upflow side pressure) drops to 0
MPa by stopping the compressor.
●If the compressor starts with the ambient temperature
below the lower limit defined in the specification, the
machine may start in about 20 seconds after 1 to 2 sec-
ond jog operation.
This sequence is controlled by the retry function and,
therefore, is not a trouble. If this is your case, “E0.44”
may be displayed on the digital monitor and the
STANDBY light blinks.
IMPORTANT
IMPORTANT
●If restarting immediately after stopping operation, “E0.57”
may be displayed on the digital monitor due to fan motor
overload protection and the compressor may stop.
If restarting after stopping, be sure to wait at least 1 min-
ute before restarting.
18
3. HOW TO OPERATE [How to Set Control Functions]

Table of Contents

Related product manuals