8.2 Typical Maintenance Standard (A) of Air CompressorIn case of annual run hour less than 6,000 hours
Maintenance part and item Check
Inspection time
Note
Reference
page No.
Daily
1-Month 6-Month
1-Year 2-Year 4-Year 8-Year
Oil level gauge
Oil level check
Oil level must be within red lines during operation.
20
Discharge air temp.
Discharge air temp. check
Must be between 65 and 100.18
Relief valve
Performance check
Check by hand. 45
Lubricant (genuine synthetic oil)
Replenish/
Analysis
(○)
Replenish every 1,000 to 1,500 hours
Sampling analysis every 3,000 hours
20,21
Motor Greasing
Use “RMS Grease” 52
Motor's cooling fin Cleaning
52
Grease Reservoir Cleaning
Clean once for every 2 grease replenishments.
52
Mechanical seal
Oil leak check
If the oil leak is 3 cc/h or higher, replace the seal even
before 8-year (48,000 hours) operation.
Air intake filter element Replacement
Clean if the error code of an element clogging
appears on the digital monitor. Replace whenev-
er the number of times of cleaning has reached
5 times even within one year interval.
47
Oil filter element Replacement
46
Oil separator element Replacement
Replace the housing and square ring as well.
50
Solenoid valve
Performance check
Cooling fans
Crack check/Cleaning
DCBL controller cooling fan
Crack check/Cleaning
Clean cooling fins and duct. 53
Fan inverter
Crack check/Cleaning
Motor
Insulation check
1M ohm or more at DC500 V Mega.
Electric panel, instruments, sensors
Inspection/Cleaning
Terminal refastening, electric line cover check and cleaning.
Pipe joints Loose check
Oil cooler, Aftercooler Cleaning
Lubricant (genuine synthetic oil)
Replacement
21
Oil level gauge Replacement
Consumable Parts
Suction throttle valve
Replacement
Replace the cap seal, valve plate, and O-ring.Clean.
Piston of minimum pressure valve /
check valve
Replacement
Replace check valve spring, O-ring at the same time.
49
Oil filling port O-ring, plug O-ring
Replacement
Suction pipe Replacement
Oil temperature control valve
Inspection/Cleaning
Change O-ring.
DCBL controller cooling fan Replacement
Including cooling fan in the starter/control box.
Fan motor bearing Replacement
If not so, clean it and continue to use it.
Thermistor Inspection
Oil temperature control valve Replacement
Check valve (1/4 inch) Replacement
Locate it on the oil-scavenging pipe from the shaft seal.
Coupling elastic body Replacement
If not so, clean it and continue to use it.
O-ring (Air end) Replacement
O-ring (Flange) Replacement
O-ring, oil separator tank O-ring
Replacement
Replace 1/2 stop valve O-ring at the same time.
DCBL motor bearing
Replacement
Mechanical seal Replacement
Compressor Air end bearing Replacement
Controller smoothing capacitor
Replacement
CPU printed circuit board,
power PCB
Check/Clean/Replace
If it is dirty or shows a change in color, replace it.
If not so, clean it and continue to use it.
Fan inverter Replacement
Replace these parts every 2 calendar years or when the
HI
SCREW has loaded/unloaded total 1,000,000 times,
whichever comes earlier. For the total load/unload times, watch the digital monitor.
43