Item Unit OSP-55VAN OSP-75VAN
Operating gas
−
Air
Suction pressure
−
Ambient pressure
Suction temperature
℃
0 to 40
PQ Wide
Mode
Function
Disabled
(Ratings)
Discharge pressure
MPa
0.7
Discharge air capacity
(1)
m
3
/min
10.0 13.2
Enabled
Discharge pressure
MPa
0.6 0.85 0.6 0.85
Discharge air capacity
(1)
m
3
/min
10.5 9.0 13.9 11.9
Working range of PQ wide mode function
MPa 0.6 to 0.85
Discharge temperature
℃
Atomospheric temperature+15
Main motor shaft power
kW 55 75
Main motor type
−
Permanent Magnet Synchronous Motor,
Totally Enclosed Fan Cooled
Main motor insulation class
−
F type
Fan motor output (rating) kW 1.5 2.2
Fan motor type
−
3-phase cage type induction, fully closed type
Fan motor insulation class
−
E type
Starter type
−
Soft start
Power supply voltage V 380・400・415 (50Hz)
Capacity control type
−
V-mode: CPCS (constant* pressure control system) motor speed
control * discharge pressure±0.01 MPa
(3)
I-mode: online/offline control with blowoff
P-mode: automatic motor stop/restart control
Motor speed control range % About 30 to 105
Lubricating oil
−
NEW
SCREW OIL NEXT (genuine synthetic oil)
Lubricating oil filling amount L
26 36
Total weight kg 1,220 1,390
Size (Width×Depth×Height) mm 2,000×1,200×1,800
NOTE
(
1
)
Discharge air capacity is a converted value according to the suction condition of the compressor.
(
2
) Discharge pressure indicates gauge pressure.
(
3
)
Discharge air temperature varies depending on ambient temperature, load ratio etc.
The interphase voltage unbalance ratio of the power supply shall be within 1 %.
If the unbalance factor of the input current exceeds 20 % during the rated load operation, install AC reactor to the input side for improvement
of power supply cooperation. (The AC reactor is NOT the scope of supply from HITACHI)
(
4
)
Applicable for the load ratio between 30 and 105 %.
(
5
)
When a unit operates at the pressure below the PQ wide mode range, size-UP may be required for separate dryer and/or filters. Contact
Hitachi authorized distributors.
(
6
) The compressor is not equipped with an earth leakage breaker. The earth leakage breaker should be provided by the customer.
(
7
) The appearance and specifi cations are subject to change without notifi cation.
(
8
) Intake temperature upper limit is 40℃ for dustproof specifi cations and optional specifi cations.
■ Compressor Specification
68
13. STANDARD SPECIFICATION