Chapter 4 Explanation of Functions
4 - 45
Ambient temperature 50 derating (reference)
(NOTE) In case of replacing with L700 combined with LCR filter, please check the type code of LCR filter
and consult for compatibility (90-160kW).
4.2.36 Automatic carrier frequency reduction
- The automatic carrier frequency reduction function automatically
reduces the carrier frequency according to the increase in output current.
- To enable this function, specify "01" for automatic carrier frequency
reduction selection (b089).
Item Function code Range of data Description
Automatic carrier
frequency reduction
b089 00/01 00: invalid, 01: valid
- When the output current increases to 60%, 72%, 84%, or 96% of the rated current, this function reduces
the carrier frequency to 12, 9, 6, or 3 kHz, respectively. This function restores the original carrier frequency
when the output current decreases to 5% lower than each reduction start level.
0.455kW 75132kW
Carrier frequency reduction start level
(Restoration level)
Carrier frequency after
reduction (kHz)
Carrier frequency reduction start level
(Restoration level)
Carrier frequency after
reduction (kHz)
Less than 60% of rated current 15.0 Less than 60% of rated current 10.0
60% (55%) of rated current 12.0 60% (55%) of rated current 8.0
72% (67%) of rated current 9.0 71% (66%) of rated current 6.0
84% (79%) of rated current 6.0 83% (78%) of rated current 4.5
96% (91%) of rated current 3.0 91% (86%) of rated current 3.0
- The rate of carrier frequency reduction is 2 kHz per second.
- The maximum limit of carrier frequency change by this function is the value specified for the carrier
frequency setting (b083); the minimum limit is 3 kHz.
Note: If 3 kHz or less frequency has been specified for b083, this function is disabled regardless of the
setting of b089.
b089: Automatic carrier frequency
reduction selection
b083: Carrier frequency setting
Related code
10.0kHz
60
Out
p
ut current
(
%
)
Carrier fre
q
uenc
y
8.0kHz
6.0kHz
4.5kHz
3.0kHz
71
83
91
0
105
5.0kH
60
Out
p
ut current
(
%
)
Carrier frequency
3.0kH
6.0kH
4.0kH
2.5kH
71 83 91
0105
11 to 75kW 90 to 160kW
30kW
Carrier frequency (kHz)
Derating of output current
22kW
200Vclass
0.5 2
4
6
8 10 12
11kW
37kW
15kW
18.5kW
60
55
100
95
90
85
80
75
70
65
50
45kW
55kW
75kW
110kW
Carrier frequency (kHz)
Derating of output current
60
55
100
95
90
85
80
75
70
65
45kW
37kW
400Vclass
0.5
4
6
8
10 12
11-18.5kW
30kW
22kW
55kW
2
50
75kW
90kW
132kW,160kW
1