Chapter 2 Installation and Wiring
2 - 22
2.2.5 Selection and wiring of regenerative braking resistor (on 11 kW to 30 kW models)
The L700 series inverter models with capacities of 11 to 30 kW have an internal regenerative braking
circuit.
Connecting an optional regenerative braking resistor to RB and P terminals increases the regenerative
torque.
Model
Motor capacity
(kW)
Without a resistor
connected
Minimum connectable resistor
Minimum
resistance
during
continuous
operation
(
Ω)
Regenerative
torque (%)
Resistance
(
Ω)
Regenerativ
e torque
()
BRD usage
rate
()
L700-110LFF 11 10 10 110 10 50
L700-150LFF 15 10 10 80 10 50
L700-185LFF 18.5 10 7.5 90 10 35
L700-220LFF 22 10 7.5 70 10 35
L700-300LFF 30 10 5 80 10 35
L700-110HFF 11 10 35 120 over 10 150
L700-150HFF 15 10 35 90 10 100
L700-185HFF 18.5 10 24 110 10 100
L700-220HFF 22 10 24 90 10 100
L700-300HFF 30 10 20 80 10 100