Chapter 4 Explanation of Functions
4 - 95
4.2.100 Torque LAD stop function
The torque LAD stop function is effective when "03" (sensorless
vector control) is specified for the V/F characteristic curve
selection (A044/A244). This function temporarily stops the
frequency-based deceleration function (LAD) when the torque
limitation function operates.
Item Function code Data or range of data Description
V/F characteristic
curve selection
A044/A244 03
Sensorless vector control
Torque limit
selection
b040
00 Quadrant-specific setting mode
01 Terminal-switching mode
02 Analog input mode
03 Option 1 mode
04 Option 2 mode
Torque limit (1) b041 0 to 150 (%)
Forward powering (in quadrant-specific setting
mode)
Torque limit (2) b042 0 to 150 (%)
Reverse regeneration (in quadrant-specific
setting mode)
Torque limit (3) b043 0 to 150 (%)
Reverse powering (in quadrant-specific setting
mode)
Torque limit (4) b044 0 to 150 (%)
Forward regeneration (in quadrant-specific
setting mode)
Torque limit
LADSTOP enable
b045
00 Disabling the torque LAD stop function
01 Enabling the torque LAD stop function
Terminal function C001 to C008
40 Whether to enable torque limitation
41 Torque limit switch 1
42 Torque limit switch 2
A044/A244: V/F characteristic curve selection,
1st/2nd motors
b040: Torque limit selection
b041 to b044: Torque limits (1) to (4)
b045: Torque limit LADSTOP enable
Related code