6. Optional functions
166
SMGB0079 rev.0 - 01/2013
Items Optional function
Individual
setting
Setting
condition
Contents
JA
Not prepared -
00 Not available
01 (Use as 00 condition)
Jb
Not prepared -
00 Not available
01 (Use as 00 condition)
K1
Not prepared x
00 Not available
01 (Use as 00 condition)
K2
Not prepared x
00 Not available
01 (Use as 00 condition)
K3
Not prepared x
00 Not available
01 (Use as 00 condition)
K4
Not prepared -
00 Not available
01 (Use as 00 condition)
K5
Motion sensor detection level -
00 Standard
01 High
02 Low
○: Allow individual setting.
×: Setting is used for all the outdoor units
-: Not used
N O T E
*1:The“02”settingmaynotbeavailableaccordingtothetypeofindoorunit.
*2:00:Standard(7-stepoperation),01:DraftPrevention(lower2stepscutoff),02:Highceiling(upper2stepscut
off)
*3:Incasethatthesettemperatureischangedandkeptwithinthesettimeat“F4”,thetemperatureisautomatica-
llychangedto“F5”and“F6”.(Incasethatthesettemperatureisoutofrangeat“F5”and“F6”,itisappliedwithin
upperandlowerlimitforthesettemperature.)
*4:Applicabletofan,coolinganddryoperationmodes.
*5:Applicabletoheatingoperationmode.
*6:Operationisstoppedbypressingthe“
”(run/stop)switchfor3seconds.
*7:Thesensorvalueat“C8”willbeindicated.Whenthethermistorforremotecontrolswitchisused,theaverage
valueofthethermistorforremotecontrolswitchandthethermistorforindoorinletwillbeindicated.
*8:Whentheunitisrestartedbytheremotecontrolswitch,thetemperatureautomaticallychangestothesetting
temperatureof“F5”or“F6”.
• Afteratleast3minutesfromthepowerON,notchangetheoptionalsetting.
• Whenchanging“CF”setting(changeoflouverswingrange),restorethepowersupplyorallowthelouverto
makeonecompleteswingfullyintheautoswingmodetoapplytheoptionalsetting.
• Theoptionalsettingsaredifferentaccordingtotheindoorandoutdoorunitmodels.Checktoensurethatthe
unithastheoptionalsettingornot.
• Recordthesettingconditionsforeachoptionalsettinginthe“Setting”columnofthetable.
• Theaboveoptionalfunctionswith“X”markattheindividualsettingcanchangetheconditiononlywhen“All
Rooms”isset.