7. Test run
175
SMGB0079 rev.0 - 01/2013
7
7.4  Test run procedure using the wireless remote control switch (PC-LH3A/B)
  N O T E
Ifthewiredremotecontrolswitchisusedorifmultiple
units (SET-FREE, DCINVERTERand utopia series) are
operating simultaneously, you cannot perform the test
runbymeansoftheremotecontrolswitch.Ifthatisthe
case,performthetestrunbymeansofthewiredremote
controlswitch.
1  Perform the test run after completing the installation. 
a.  Set the batteries for the remote control switch.
b.  Turn ON the power source of the indoor units and the 
outdoor units.
c.  The yellow ‘‘ LED on the receiver of the indoor unit 
ickers  (0.25  seconds  ON  ↔  0.25  seconds  OFF). 
Then,  the  yellow  LED  turns  OFF.  While  the  LED  is 
ickering, the unit will not operate because the unit is 
initializing.
2  Set the TEST RUN mode by pressing the SET switch and 
the OFF TIME switch simultaneously for more than three 
seconds. The LCD should look like the LCD on the right 
gure. The TEST RUN mode is not operating
3  Set the  operation mode  by pressing the  MODE switch. 
The TEST RUN mode is operating.
4  Operate the test run by pointing the transmitter towards the receiver of the indoor unit. Then, press the RUN/STOP 
switch. When the indoor unit receives the commands, the yellow ‘‘ LED of the receiver will turn on briey. Make 
sure that the commands are received well and the selected mode 3) is set correctly. In the TEST RUN mode, the red 
RUN LED of the receiver is turned ON and the green TIMER LED ickers (0.5 seconds ON ↔ 0.5 seconds OFF) (*2). 
Then, the timer switches off for two hours.
  N O T E
• Iftheyellow‘’LEDdoesnotturnON,thecommandsfromtheremotecontrolswitchmaynothavereached
thereceiver.Sendthecommandsagain.
• (*2)InthecaseoftheRPKmodel,theTIMERLEDisturnedOFF.
5  Adjust the angle of the air grille as follows. The air louver has a mechanism for the auto-swing function. Do not move 
the louver by hand forcefully.
a.  Select the FAN mode by pressing the MODE switch.
b.  Set the louver angle by pressing the LOUVER switch.
6  Stop the test run (normal)
a.  The test run stops automatically after two hours.
b.  You stop the test run by pressing the RUN/STOP switch again. After the test run has nished, check that the red 
RUN LED and the green TIMER LED turn OFF.
7  Stop the test run (abnormal) for the PC-ALHD/PC-ALHZ. If you cannot use the PC-LH3A because of battery shortage 
or any other reason, perform the emergency operation as follows.
a.  COOL switch: Press the COOL switch in order to start the cooling process. Press the COOL switch again in order 
to stop the cooling process.
b.  HEAT switch: Press the HEAT switch in order to start the heating process. Press the HEAT switch again in order to 
stop the heating process.
  N O T E
Duringtheemergencyoperation,theyellowLEDblinks(0.5secondsON/0.5secondsOFF).