General Index
iv
SMGB0079 rev.0 - 01/2013
3. Piping work and refrigerant charge ............................................................................ 51
3.1  General notes before performing pipe work .............................................................................................52
3.1.1  Piping Materials ............................................................................................................................................. 52
3.1.2  Three principles on refrigerant piping work ................................................................................................... 54
3.1.3  Suspension of refrigerant piping .................................................................................................................... 54
3.1.4  Brazing work .................................................................................................................................................. 55
3.2  Piping connection for outdoor unit ............................................................................................................56
3.2.1  RAS-(2-2.5)HVNP / RAS-3HVNC ................................................................................................................. 56
3.2.2  RAS-3HVNPE / RAS-(4-6)H(V)N(P/C)E / RAS-(8-10)HN(P/C)E / RAS-12HN(P/C) ..................................... 57
3.2.3  Outdoor unit stop valve ................................................................................................................................. 60
3.3  Refrigerant piping range ...........................................................................................................................62
3.3.1  Refrigerant piping length ............................................................................................................................... 62
3.3.2  Piping system for header branch ................................................................................................................... 62
3.3.3  Piping system for line branch ........................................................................................................................ 65
3.3.4  Combinations of piping size and piping length .............................................................................................. 66
3.3.5  Refrigerant piping size and multikit/distributor selection ............................................................................... 67
3.3.6  System installation ........................................................................................................................................ 70
3.3.7  Connecting are adapter ............................................................................................................................... 71
3.4  Refrigerant charge ....................................................................................................................................72
3.4.1  Caution of the pressure by check joint .......................................................................................................... 73
3.4.2  Refrigerant charge quantity ........................................................................................................................... 74
3.5  Caution in case of refrigerant leakage ......................................................................................................78
3.5.1  Maximum permitted concentration of hydrouorocarbon (HFC) ................................................................... 78
3.5.2  Calculation of refrigerant concentration ......................................................................................................... 78
3.5.3  Countermeasure for refrigerant leakage ....................................................................................................... 78
3.6  Piping work for compatibility with the piping of current installations where is used R22 or R407C.  ........79
3.6.1  Installation procedure for existing pipes ........................................................................................................ 79
3.6.2  When existing Air-Conditioner is a product of another manufacturer ............................................................ 79
3.6.3  Permissible range for existing Air-Conditioning Pipes  
(Pipe length in the case of “without cleaning process”. ........................................................................................... 80
3.6.4  Renewal kit selection model .......................................................................................................................... 81
3.7  Drain piping...............................................................................................................................................85
3.7.1  Drain discharging boss .................................................................................................................................. 85
4. Electrical wiring ............................................................................................................ 87
4.1  General notes ...........................................................................................................................................88
4.1.1  General check ............................................................................................................................................... 88
4.2  Electrical wiring connection for the outdoor unit .......................................................................................90
4.3  Setting the DIP switches for the outdoor unit ............................................................................................92