EasyManua.ls Logo

Hitachi RAS-3-HVNC - Page 281

Hitachi RAS-3-HVNC
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8. Troubleshooting
267
SMGB0079 rev.0 - 01/2013
8
(9) No Function
This function is not used.
Press “OK” to proceed.
0 7 : 0 0 0
Self Checking
(10) Transmission Circuit Test
The remote control switch automatically starts to check the
transmission circuit.
(11) Remote Control Switch Thermistor Test
The temperature detected by remote control switch thermistor
is displayed at “
A
” in the right gure.
0 9 : 0 2 5
Self Checking
(12) Date/Time Test
The date and time is switched from “2012.03.04 12:34” to “2008.
01. 01 00:00”.
1 0 : 0 0 0
2008.01.01 00:00
Self Checking
(13) EEPROM Test
< EEPROM Clearing Cancel >
Press “?“ (help).
< EEPROM Clear >
Press “OK” or wait 15 seconds. EEPROM data will be cleared.
During the process, the numbers will be indicated on where “
A
” is located.
If
A
indicates “999”, EEPROM is in a faulty condition.
*In case “
A
” indicates “999”, the process does not proceed
to next step.
1 1 : 0 0 0
Self Checking
(14) After the several seconds pass, the self checking is completed and the remote control switch automatically restarts.
EEPROM process
(15) Clear EEPROM
The remote control switch will automatically start EEPROM
clearing process.
1 3 : 0 0 0
Self Checking
(16) After the several seconds pass, the self checking is completed and the remote control switch automatically restarts.

Table of Contents

Related product manuals