EasyManua.ls Logo

Hitachi RAS-3-HVNC - Page 351

Hitachi RAS-3-HVNC
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10. Servicing
337
SMGB0079 rev.0 - 01/2013
10
6  Remove the crankcase heater.
7  Remove the suction pipe and discharge pipe from the compressor. Remove the brazed part after cutting the pipes at
“A” by a pipe cutter.
N O T E
Besuretoseparatetheblazingburneramesufcientlyfromthewiresandelectricalcomponentsaround
thebrazedpartinordertoavoidburning.
Suction Pipe
Brazing Part
Discharge Pipe
A
A
Discharge Pipe
Brazing Part
Suction Pipe
8  Remove 1 nut which x the compressor and remove it by lifting up.
Nut
Vibration-Proof
Rubber
1
2
3
Vibration-proof
Rubber
Nut
Compressor Position 1 2 3
Vibration-Proof
Rubber
Nut - -
: with a nut
- : without a nut
9  When brazing the replaced compressor braze quickly cooling the pipes on the compressor side with wet cloth to avoid
the ller metal entering into the compressor.
N O T E
PAYCLOSEATTENTIONnottoletthellermetalenterintothecompressorwhichmayresultincompressor
damage.

Table of Contents