5  REMOTE CONTROLLER OPERATION 
5.1.  OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-ART
Liquid crystal display (LCD)
Model: PC-ART
 Fan speed indicator
Indicates the ventilation speed selected:
 - (High / Medium / Low)
  Indicator of Total ventilator
Indicates if the total heat exchanger has been selected.
 - A/C  only air conditioning
 - VENTI  only ventilation
 - A/C + VENTI  if both are selected
 Operation Mode Indicator
Indicates the operation mode selected:Fan/Cool/Heat/Dry/Auto 
(Cool/Heat)
 Run indicator (Red lamp)
 RUN/STOP switch
 MODE (Operation Mode Selection) switch
 FAN SPEED (Fan Speed Selection) switch
 Up & down panel operation switch
 VENTI (ventilator operation) switch
 LOUVER (deector panel) switch
 SELECT (Day/Schedule) switches
Increase and decreases the Day/Schedule for timer operation.
ON/OFF TIMER switch
Used to activate or deactivate the timer operation.
 OK switch
RESET (Filter Reset Switch)
After cleaning the air lter, press the “RESET” button. FILTER 
indication will disappear and the next lter cleaning time is reset. It 
also stops the run procedure.
 TEMP (temperature setting) switches
T.RUN (test run indication)
Check (check indication) 
These tests appear when TEST RUN or CHECK are being 
performed.
 ABNML (alarm) indicator
 SET TEMP (set temperature) indicator
1234S indicator (setting schedule number)
 Mon Tue ... Sun indicator (day of the week indicator).
Indicates that central station or CSNet control is operating.
 Swing louver indicator
DEFROST indicator
SERVICE mode indicator.
Indicates the change to special operations
Time indicator.
Time indicator. (Indicates the programmed time).
To open the cover, pull in the 
direction of the arrow.
 NOTE:
 - If the LOW fan speed is selected and the outdoor temperature is 
higher than 21°C, the compressor is subjected to an excessive 
load when operating in heating mode. 
Therefore, the fan speed should be set to HIGH or MEDIUM to 
avoid activating the safety devices.
 - When the system is restarted after a shutdown of more than 
approximately 3 months, the system should be checked by your 
service provider.
 - Turn off the main switch when the system is to be inoperative for 
a long period of time. Otherwise the system consumes electricity 
as the oil heater remains active even though the compressor is 
stopped.
DAY
SCHEDULE
SELECT
LOUVER
VENTI
MODE
FAN SPEED TIMER
RESET
OK